Stream/Non-Flow and Blocked Chute Detection – Sensor Overview
General
The MWS-DP-3 Microwave Solids Flow Sensor recognizes moving solids by using profoundly infiltrating microwaves and the Doppler impact. The detecting head sends microwaves toward the objective material. A part of the microwaves are reflected back to the detecting head and broke down with regards to whether they are from a moving or fixed item. The exceptionally vulnerable microwaves can go fall detection alarm system through a development on the head and surprisingly through pipe made of non-leading materials like plastics. It is the most appropriate for recognizing such materials as powder, granules, and so on, traveling through a vacuum pipeline.
Exceptional Features
Hindered Chute Detection
As well as being utilized as a solids stream sensor, it tends to be utilized as a transmitter in mix with a recipient to distinguish a hindered chute.
Furnished With a Filter for Screening Unnecessary Incoming Doppler Signals
This capacity wipes out superfluous approaching Doppler signals, for example, the signs from a vibrating line or transport and works on the S/N proportion. This empowers the sensor to be utilized where beforehand, non contact stream identification was beyond difficult.
Furnished With a Sensitivity Margin Indicator
The got power level and the affectability set point are demonstrated on the sensor considering simple visual change and upkeep of the sensor. The pointer plainly shows the upside of the channel screening impact.
Application Examples
Stream/Non Flow Detection
Because of the channel work, the solids stream sensor distinguishes just the falling material without obstruction from transport 1 or 2.
Stream/Non-Flow and Blocked Chute Detection
The beneficiary gets microwave radiates from the solids stream sensor. At the point when the shaft is intruded on, the recipient will yield a “hindered chute” signal. The working distance between the Solids Flow Sensor and Receiver is up to 80 meters (standard sort) however may fluctuate from one sensor to another and as per establishment conditions. At the point when the MWS-SR-2 beneficiary is utilized for this application, its channel work can’t be utilized.